Banner
Vortex flowmeter

Vortex flowmeter

Product Details

I. Overview

The LUGB series of vortex flowmeters is a state-of-the-art new flowmeter developed using the Karman vortex principle. This product is mainly used to measure the flow of fluids in industrial pipeline media, such as steam, liquid, gas and other media. This flowmeter has a large measuring range, high accuracy and low pressure loss. It is difficult to be affected by parameters such as density, viscosity, pressure and temperature of the fluid when measuring the volumetric flow rate. The piezoelectric stress sensor in our vortex flowmeter allows it to operate from -20 ° C to +250 ° C with high reliability. In addition, the product has analog standard signal and digital pulse signal output, which can be used with digital systems such as computers.

Second, unique characteristics

l Simple structure, no moving parts.

l Easy maintenance and easy installation.

l High reliability, high measurement accuracy, no on-site debugging.

l The detection sensor does not directly contact the medium to be tested, so the life is long and the performance is stable.

l It can be networked with computers to transmit traffic signals over long distances and achieve centralized management.

l Uniquely designed magnifying plate, universal gas and liquid.

l Wide measurement range with a range ratio of 1:20.

l The pressure loss is small and the operation cost is low.

Third, technical indicators

l Accuracy level: 1.0 1.5

l Nominal pressure: 1.6MPa, 2.5MPa, 4.0MPa and above

l Temperature of the measured medium: -40 ° C ~ 350 ° C

l Pressure loss: 12~24VDC

l Explosion-proof level: IaIICT6 (intrinsic explosion-proof)

l Output signal: voltage pulse low level ≤ 1V high level ≥ 6V, standard current signal 4~20mA

Fourth, the flow range

Sensor diameter (mm) Liquid (checking medium: normal temperature water)

gas

(Verification medium: air at 20 ° C, 101,325 Pa)

Standard type Extended type
15 0.8~6 0.5~8 6~40 5~50
20 1~8 0.6~12 8~50 6~60
25 1.5~12 0.8~16 10~80 8~120
40 2.5~30 2~40 25~200 20~300
50 3~50 2.5~60 30~300 25~500
65 5~80 4~100 50~500 40~800
80 8~120 6~160 80~800 60~1200
100 12~200 8~250 120~1200 100~2000
125 20~300 12~400 160~1600 150~3000
150 30~400 18~600 250~2500 200~4000
200 50~800 30~1200 400~4000 350~8000
250 80~1200 40~1600 600~6000 500~12000
300 100~1600 60~2500 1000~10000 600~16000
400 200~3000 120~5000 1600~16000 1000~25000
500 300~5000 200~8000 2500~25000 1600~40000
600 500~8000 300~10000 4000~40000 2500~60000

Five, installation conditions

The sensor should be mounted on a pipe that is vertical , inclined (liquid flow from bottom to top) , and horizontally the same diameter. The upstream and downstream of the sensor shall be equipped with a straight pipe section of a certain length, the length of which shall comply with the requirements of the front straight pipe section 15~20D and the rear straight pipe section 5~10D.

The nearby pipe in which the liquid sensor is installed must be filled with the liquid to be tested. The sensor should not be installed on pipes with strong mechanical vibration.

The inner diameter of the straight pipe section should be consistent with the sensor diameter. If not, the pipe with a slightly larger diameter than the sensor should be selected. The error should be ≤3% and not more than 5mm.

When the measured medium contains more impurities, a filter should be installed in addition to the required length of the straight pipe upstream of the sensor.

The sensor should not be installed in a small space, where the electromagnetic field is strong, and the space is small, which is not conducive to maintenance.

caliber L1 L2 D1 D2 H D3 N
20 65 95 125 100 460 13 4
25 65 95 125 100 460 13 4
40 75 109 145 110 470 13 4
50 75 109 160 125 481 17 4
65 75 117 180 145 497 17 6
80 80 122 195 160 510 17 6
100 90 132 230 190 544 17 8
125 100 146 245 210 564 17 8
150 120 170 280 240 594 twenty one 8
200 150 200 335 295 656 twenty one 12
250 160 214 405 355 708 twenty one 12
300 170 224 460 410 760 twenty one 12

 

Inquiry

Customer Service Hotline:13938765366

Company Telephone:13938765366

公司传真:0755-66803070

Office Mailbox:Tianchenyb@163.com

Company Address:North Section of Yuanxin Road, Xinxiang City, Henan Province

Mobile