Color paperless recorder

Color paperless recorder

Product Details

I. Overview

XME7000 color screen paperless recorder maximum 16-channel universal input color screen paperless recorder, can input standard current, standard voltage, frequency, millivolt, thermocouple and other signals. It has sensor power distribution output, relay alarm output, transmission output, flow accumulation, cumulative report, historical data transfer, printing and remote communication.


Second, the function description

Features Description
display Imported 5.7-inch 320*240 dot matrix TFT high-brightness color graphic liquid crystal display, CCFL backlight, clear picture, beautiful color, wide viewing angle, free adjustment of screen brightness
data collection High-speed, high-performance 32-bit ARM microprocessor with a picture response time of less than 0.2 seconds, enabling simultaneous 12-channel signal acquisition, recording, display and alarm
storage Using 32M large-capacity FLASH flash memory chip to store historical data, power loss will never lose data; according to different recording intervals, can store 72 hours to 720 days of data
input signal Fully isolated universal input, can input multiple signals at the same time, no need to replace the module, can be configured through software
Display range The value range of the displayed engineering quantity data is wider, and the 5-digit value can be displayed: -9999~19999
Operation interface New input method, easy to operate, support Chinese pinyin input, digital, English, special symbols, superscript and other selection input, Chinese character number, unit custom combination input
Storage function Equipped with standard USB interface, support USB1.1, 2.0 USB flash drive, support FAT16/FAT32 file system. Quick and easy transfer of historical data
Communication/printing

Standard serial communication interface: RS-485 and RS-232C; standard open Modbus communication protocol. With RS-232C serial micro printer interface, manually print data,

Curve, automatic timing print data to meet the needs of users on-site printing

Internal clock Integrated hardware real-time clock, the clock can also run accurately under power failure, and the instrument hardware clock is convenient for enterprise measurement management.
Power supply With a new switching power supply, it can work normally in the range of 100~240VAC of AC power.
isolation All-aluminum sealed housing and internal shielding plate ensure that the instrument works properly in harsh environments


Third, the input specifications  

Input type Measuring range Input type Measuring range (°C)
Type II: 0~10mA, 0~5V -9999~19999 Thermocouple B 500~1800
Type III: 4~20mA, 1~5V -9999~19999 S 0~1600
20mV 0~20mV K 0~1300
100mV 0~100mV E 0~1000
Frequency Fr 0~10kHz J 0~1000
Resistance 0~350Ω -9999~19999 R 0~1600
Thermal resistance Cu50 -50~140°C N 0~1300
Cu53 -50~140°C T 0~380
BA1 -100~600°C WRe5-26 0~1800
BA2 -100~600°C Radiation pyrometer F1 700~2000
Pt100 -100~600°C F2 700~2000


Fourth, technical parameters  

monitor 5.7-inch TFT color graphics LCD, 320*240 dot matrix, CCFL backlight, wide viewing angle
Basic error ±0.2%F·S ±1 word
Input specification

Fully isolated universal input: 1~12 channel signal input, full isolation between channels, isolation voltage greater than 400V

Sensor power distribution: 24VDC analog output: 4~20mA output

12-way configurable relay contact output: contact capacity is 3A/250VAC (resistive load)

Alarm output: upper limit, upper limit, lower limit, lower limit

Compensation operation

Steam.........calculating the density of superheated steam by calculating the vapor density according to the IFC67 formula

General gas...temperature, pressure compensation measurement standard volume flow

Natural gas.........temperature, pressure compensation measurement standard volume flow

Liquid............temperature compensation measurement standard volume flow or mass flow

Compensation range

Steam: General gas:

Pressure 0.1~4.5MPa Pressure 0~60MPa

Temperature 100~500°C Temperature-100~500°C

Density 0.1~100kg/m3 Liquid Humidity-100~500°C

Comparison 2508~3224kJ/kg

Cumulative range 0~99999999
Recording time

Recording interval: 1, 2, 5, 10, 15, 30, 60, 120, 240 seconds optional

Record length: eight records, 72 hours / pen (record interval 1 second) ~ 720 days / pen (record interval 4 points)

Communication/printing

Communication interface: RS232C or RS485

Baud rate: 1200, 2400, 9600, 57600

Print interface: RS232C direct connection to micro printer

Data backup and dump 128M, 256M, 512M, 1G and larger U disk optional
Thermocouple cold compensation error ±1°C
Power failure protection Built-in FLASH memory protection parameters and historical data, can be permanently saved after power off, integrated hardware clock, can also run accurately after power off
power supply Switching power supply: 100~240VAC (50Hz/60Hz)
Ambient temperature 0~50°C
environment humidity 0~85%RH


Five, selection type spectrum

Code Description
XME Integrated instrument series

meter

Input

70 150×150×252mm
01~12 Universal input Input channel 01~12
Frequency input N No input
F01~12 Universal input + frequency input ≤ 12 Frequency signal input quantity
R True color paperless recorder
Relay alarm output (configurable) 00 no output
01~12 01~12 alarm points
Transmission and PID adjustment output (occupying 9~12 channels) N no output
A1 All the way to send output
A2 Two-way transmission output
A3 Three-way transmission output
A4 Four-way transmission output

Note:

1. The frequency input cannot be mixed with other signals in 9~12 channels.

2, the number of transmission output + adjustment output number ≤ 4

N no output
C1 One way PID adjustment output
C2 Two-way PID adjustment output
C3 Three-way PID adjustment output
C4 Four-way PID adjustment output
Communication/printing function 0 no output
1 RS-232C communication
2 RS-485 communication
3 RS-232 printing
Ethernet communication N no output
E Ethernet communication
Power distribution output N No power distribution output
P DC24V power distribution output
Flow calculation 0 no output
1

Flow product without temperature and pressure compensation

Instrument

2

Flow product with temperature and pressure compensation

Instrument

USB rollover function /0 No transfer function
/U USB rollover function

 

Inquiry

Customer Service Hotline:13938765366

Company Telephone:13938765366

公司传真:0755-66803070

Office Mailbox:Tianchenyb@163.com

Company Address:North Section of Yuanxin Road, Xinxiang City, Henan Province

Mobile

  • Scanning ConcernsHenan Tianchen Measurement and Control Instrument Co., Ltd.